Part Number Hot Search : 
C1061 00C12 24C04 MAC04003 2A20111 200BZC MTZJ27B1 NTE7038
Product Description
Full Text Search
 

To Download MV5474C Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 T-1
SOLID STATE LAMPS
RED DIFFUSED YELLOW DIFFUSED HER DIFFUSED MV5074C MV5374C MV5774C RED DIFFUSED GREEN DIFFUSED MV5075C MV5474C
PACKAGE DIMENSIONS
FEATURES
* Copper leads * Solid-state reliability
C L .130 (3.30) .115 (2.92) .210 (5.33) .190 (4.38)
DESCRIPTION
These solid state indicators offer a variety of color selection. The High Efficiency Red, Green and Yellow devices are made with a gallium arsenide phosphide LED on gallium phosphide substrate. All are encapsulated in epoxy packages. Their small size (approximately T-1 size), good viewing angle, and small square leads contribute to their versatility as all purpose indicators.
.020 (.508) 1.00 (25.4) MIN
.075 (1.91) .025 (.64)
.060 (1.52) .050 (1.27) .160 (4.06) DIA .150 (3.81)
.018 (.460) .012 (.305) SQ. TYP. (2X)
CATHODE REF FLAT
2001 Fairchild Semiconductor Corporation DS300037 11/02/01
1 OF 4
www.fairchildsemi.com
T-1
SOLID STATE LAMPS
ABSOLUTE MAXIMUM RATING
Parameter Power Dissipation Derate linearly from 25C Continuous Forward Current (MV5374C=20 mA) Peak Forward Current - (sec pulse 0.3% duty cycle) (MV5474C=90 mA) (MV5374C=60 mA) Reverse Voltage (IR = 100 A) Lead Soldering Time at 260C (See Note 1) Operating Temperature Storage Temperature (TA =25C Unless Otherwise Specified) Symbol PD IF IFM VR TSOL TOPR TSTG (TA =25C) MV5075C 0.6 1.5 1.6 2.0 20 660 100 90 MV5374C 1.5 9.0 2.1 3.0 35 585 100 90 MV5474C 1.2 9.0 2.2 3.0 35 565 100 90 MV5774C 1.5 9.0 IF = 20mA VF 1.6 2.0 20 p 660 100 2 1/2 70 2.0 3.0 45 635 100 90 See Fig. 3 IF = 20mA IF = 20mA VR = 5.0V Condition IF = 20mA IV 0.7 2.5 Rating 105 -1.14 35 35 5 5 -55 to +100 -55 to +100 Units mW mW/C mA mA V sec C C
ELECTRICAL / OPTICAL CHARACTERISTICS
Part Number Luminous Intensity (mcd) Minimum Typical Forward Voltage (V) Typical Maximum Spectral Line Half Width (nm) Peak Wavelength (nm) Reverse Current (A) Maximum Viewing Angle (Total) () Symbol MV5074C
1. The leads of the device were immersed in molten solder at 260C, to a point 1/16 inch (1.6 mm) from the body of the device per MIL-S-750, with a dwell time of 5 seconds.
www.fairchildsemi.com
2 OF 4
11/02/01 DS300037
T-1
SOLID STATE LAMPS
TYPICAL PERFORMANCE CURVES
Fig. 1 Forward Current vs. Forward Voltage
100 YELLOW 90
(TA =25C)
Fig. 2 Luminous Intensity vs. Forward Current
40
IF - FORWARD CURRENT (mA)
RED
LUMNOUS INTENSITY
80 70 60 50 40 30 20 10
HER
30
20
GREEN
10
0 0 1 2 3 4 0 20 40 60 80
VF - FORWARD VOLTAGE (V)
IF - FORWARD CURRENT (mA)
Fig. 3 Spatial Distribution
-20 -30 -40 -50 -60 -70 -80 -90 100 MV5074C -10 0 10 20 30 40 50 ALL OTHER 60 70 80 90
80
60
40
20
0
20
40
60
80
100
REL. LUMINOUS INTENSITY (%)
Fig. 4 Relative Intensity vs. Peak Wavelength
120 GREEN YELLOW HER RED
RELATIVE INTENSITY (%)
100
80
60
40
20
0 520
540
560
580
600
620
640
660
680
690
- WAVELENGTH (nm)
DS300037
11/02/01
3 OF 4
www.fairchildsemi.com
T-1
SOLID STATE LAMPS
DISCLAIMER FAIRCHILD SEMICONDUCTOR RESERVES THE THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE TO ANY PRODUCTS HEREIN TO IMPROVE RELIABILITY, FUNCTION OR DESIGN. FAIRCHILD DOES NOT ASSUME ANY LIABILITY ARISING OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT DESCRIBED HEREIN; NEITHER DOES IT CONVEY ANY LICENSE UNDER ITS PATENT RIGHTS, NOR THE RIGHTS OF OTHERS. LIFE SUPPORT POLICY FAIRCHILD'S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body,or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance with instructions for use provided in labeling, can be reasonably expected to result in a significant injury of the user. 2. A critical component in any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
www.fairchildsemi.com
4 OF 4
2/27/01
DS300005
This datasheet has been download from: www..com Datasheets for electronics components.


▲Up To Search▲   

 
Price & Availability of MV5474C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X